What This Job Takes In

Tract homes with prefab fireplaces hide the flue pipe inside a stucco or sided enclosure, and a thin galvanized lid keeps rain out of it. That lid rusts, sags and holds water; brown streaks down the stucco give it away. We measure the enclosure and pipe position, have a stainless lid folded with crossed breaks so it sheds, skirts lapping the walls and a sealed ring at the pipe, then refit the maker's cap. Tustin pricing is written after measuring.

Enclosure and pipe position measured on the roof
Stainless lid folded to those numbers
Crossed breaks so water cannot pond
Skirts lapping the enclosure walls
Ring at the pipe sealed against wind-driven rain
Maker's cap refitted above

A Timber Shaft With a Metal Lid

A great many houses and townhomes in Tustin and across Orange County have a fireplace that never involved a bricklayer. The firebox is a steel unit made in a factory. Its flue is an insulated metal pipe. And the chimney you see from the street is carpentry: a tall shaft framed in timber, sheathed, and finished in the same stucco or boarding as the walls. The pipe runs up the middle of that shaft with an air gap around it. Across the open top lies a single piece of sheet metal, cut out in the middle to let the pipe through, and the pipe's own rain cap stands over that. That sheet is the chase cover, and everything inside the shaft depends on it. Builders nearly always fitted galvanized steel, flat, with the seams and screw heads exposed. It lasts a couple of decades. Then the zinc gives out, the sheet sags between its edges, rainwater ponds in the hollow, and rust eats through around the pipe and at the corners.

From there the damage moves indoors without much warning. Water drops into the shaft and lands on the steel top of the firebox, which rusts from above where nobody looks, wetting the studs and sheathing on its way. Rust-brown streaks down the stucco below the chimney top are usually the first outward sign; a damp smell from the fireplace or a mark on the wall above it comes later. Fire adds its own damage. In a factory-built system a flue fire can buckle the inner wall of the pipe, and the heat at the top can distort the cover and cook the sealant around the pipe collar. During a wind-driven brush fire, a rusted-through cover is also a way in for embers, and what lies under it is dry timber. So after any fire event near a framed chimney we lift or look under the cover, check the top of the shaft for charring and rot, and examine the pipe, which if damaged must be replaced with the same listed system.

A Cover Folded for Your Chimney, and the Quote Behind It

A replacement cover is fabricated, not bought ready-made, because chase tops vary by inches and the pipe is seldom dead center. On the roof we record the outside length and width of the shaft top, where the pipe comes through and its diameter, and how square the corners are. The new cover is folded from one sheet of stainless steel. Its surface is creased from corner to corner so the middle stands slightly high and rain cannot pond. Its edges are bent downward into a rim that laps over the top of the stucco, with a kicked-out lip at the bottom so runoff drips away from the wall instead of streaking it. Around the pipe opening the metal is turned up into a raised ring, and a weather collar on the pipe sheds water over that ring. The old cover comes off, the top of the framing is repaired if it has rotted, the new cover is fastened through its rim, where screws stay dry, and the rain cap is refitted or replaced.

Chase covers have no flat price here. The dimensions of the shaft, the number of pipes through it, the gauge of steel and how the roof is reached all move the figure, and so does any repair to the framing or stucco that the old cover's failure has caused. After the roof visit you get a written quote listing the cover, the collar, the cap if it needs replacing, and any carpentry, each as its own line. Where a fire has been involved the quote also records what we saw of the pipe and the shaft, and if the pipe is damaged it says plainly that the fireplace must not be used until the listed replacement sections are in; a Level 2 inspection, $370, is how the full length of that pipe gets checked. If the firebox itself has rusted out from years of leaking, we tell you that too, before you spend money on a lid for a fireplace that is finished. Owners and HOA boards in Tustin, Santa Ana, Anaheim and Buena Park can request the roof visit on the contact page.

How Coffey Chimney Services Runs This Job

Filmed First

The flue is swept bare and filmed ahead of any verdict

Dated Record

Photographs carry the visit date for insurers and buyers

Priced on Paper

A scope sheet you accept or decline one line at a time

Burn Verdict

A plain yes, not yet or no on lighting the fireplace

Cities booked for chimney chase cover

Pick a city to read how its housing and weather bear on this work, and which ZIP codes the crew visits.

Full list of cities

That name is not on this list. Try the spelling again, or the city bordering yours.

The Other Jobs We Book

Chimney Sweep

Post-fire and routine sweeping that strips burnt creosote, ash and nest debris off the flue walls, leaving the liner bare for judging.

Read about it →

Chimney Inspection

Two depths of inspection: a visual pass over every part we can reach, or a filmed survey of the liner after an incident.

Read about it →

Chimney Repair

Fire-cracked tile, heat-loosened brick and split tops put right from a scope naming each defect beside its fix.

Read about it →

Fireplace Inspection

Room-side survey of firebrick, throat, lintel, hearth slab and surround for heat damage, smoke tracks and gaps toward framing.

Read about it →

Fireplace Repair

Spalled firebrick, burnt-out back walls, sagging lintels and smoke-leaking surrounds rebuilt until the box can hold a fire again.

Read about it →

Chimney Level 2 Inspection

Filmed liner survey with attic, roof and firebox checks, delivered as a dated report an insurer, buyer or contractor can act on.

Read about it →

Chimney Cap Installation

Ember-screened tops in stainless or copper, measured on the roof and fixed to flue tile, masonry or a factory pipe.

Read about it →

Chimney Flashing Repair

Lifted, rusted or tar-patched sheet metal at the roofline replaced with stepped and counter pieces let into the mortar.

Read about it →

Chimney Masonry Repair

Heat-shocked joints, popped brick faces and quake cracks cut back and relaid in a mortar chosen for that brick.

Read about it →

Chimney Rebuilds

Stacks too cracked, tilted or fire-damaged to patch are dismantled to the first solid course and raised again with new liner.

Read about it →

Fireplace Cleaning

Firebox, grate, doors and smoke-marked surround cleaned of ash, soot film and the stale burnt smell a bad fire leaves.

Read about it →

Gas Fireplace Cleaning

Yearly strip-down of a gas unit: glass off, ports and pilot cleared of dust and soot, logs reseated, vent path confirmed open.

Read about it →

Gas Fireplace Repair

Dead pilots, weak millivolt signals, stuck valves and silent remotes diagnosed by meter and mended with parts listed for the model.

Read about it →

Fireplace Remodel

Smoke-stained or fire-damaged surrounds, hearths and mantels replaced once the firebox and flue behind them are proven fit.

Read about it →

Fireplace Inserts

Gas, wood or pellet heaters fitted inside a masonry firebox on their own steel liner, a common answer to a cracked flue.

Read about it →

Pellet Stove Repair

Jammed augers, dead igniters, noisy blowers and tripped safety switches found by testing each circuit after a deep clean.

Read about it →

Wood Stove Repair

Overfired stoves brought back to spec: sagged baffles, split brick liners, hardened door rope and leaking pipe joints replaced.

Read about it →

Gas Logs

Ceramic log sets over a gas burner for owners done with wood fires, fitted only after the flue and firebox pass inspection.

Read about it →

Chimney Seismic Retrofit

Unreinforced brick stacks held to the house with steel, or shortened and finished in a lighter flue, ahead of the next shake.

Read about it →

Chimney Crown Repair

Split or crumbling mortar tops resurfaced, or broken off and recast, closing the route rain takes into the brickwork below.

Read about it →

Dryer Vent Cleaning

Lint cleared from the whole dryer exhaust run, wall hood or roof jack included, with airflow measured before and after.

Read about it →

Chimney Liner Installation

New stainless flue path dropped inside a fire-cracked or unlined stack, matched in diameter to what will burn below.

Read about it →

Chimney Leak Repair

Water entry at the stack tracked to its true opening by attic check and controlled wetting, then closed at that point.

Read about it →

Chimney Waterproofing

Breathing silane-siloxane treatment sprayed on mended brick so winter rain sheds while trapped damp can still dry out.

Read about it →

Chimney Damper Repair

Throat plates twisted by a flue fire or rusted in place freed, replaced, or retired for a cable-worked lid at the flue top.

Read about it →
Call (657) 216-0708